Siemens 5SJ4 111-7HG41 Miniature Circuit Breaker Single Pole 5 Amp DIN Rail.
Model
product brand name
SENTRON
product designation
Miniature circuit breakers
design of the product
Miniature circuit-breaker 5SJ4
General technical data
number of poles
2
number of poles / note
2P
tripping characteristic class
C
mechanical service life (switching cycles) / typical
10 000
installation environment regarding EMC
Suitable for environment B (immunity to interference not applicable)
reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750
F
overvoltage category
3
degree of pollution
3
Voltage
insulation voltage / at AC / rated value
440 V
Supply voltage
type of voltage
AC/DC
supply voltage / at AC / rated value
400 V
operating voltage
● at AC / acc. to UL 489 and CSA C22.2 No. 5-02 / maximum
240 V
● at DC / rated value / maximum
60 V
● at DC / single channel / acc. to UL 489 and CSA C22.2 No. 5-02 / maximum
60 V
● at DC / 2-channel / acc. to UL 489 and CSA C22.2 No. 5-02 / maximum
125 V
Protection class
protection class IP
IP20, with connected conductors, IP 40 in the handle range
Switching capacity
switching capacity current
● acc. to EN 60898 / rated value
10 kA
● acc. to IEC 60947-2 / rated value
15 kA
Dissipation
power loss [W] / for rated value of the current / at AC / in hot operating state / per pole
1.8 W
Current
operational current
● at 30 °C / rated value
● at 40 °C / rated value
● at 45 °C / rated value
● at 50 °C / rated value
● at 55 °C / rated value
● at 60 °C / rated value
● at AC / rated value
Main circuit
Product details
2A 2A 1.9 A 1.9 A 1.8 A 1.8 A 2A
240
Mechanical engineering / industry
No Yes
No No Yes Yes
Yes Yes Yes Yes
Terminal tightening torque for Cu, 60/75°C; 3.5Nm/31lb.in 14 kA
0.75 mm2 25 mm2
3.5 N·m Any
110 mm 36 mm 70 mm 70 mm 2
on standard mounting rail any
339 g
max. 95% humidity
50 m/s2 at 25 to 150Hz and 60m/s2 at 35Hz (4sec)
type of voltage supply / at AC / acc. to UL 489 and CSA C22.2 No. 5-02
suitability for operation
product function / neutral conductor switching
product feature / touch protection
product component
● tunnel terminals top
● tunnel terminals bottom
● combined terminal top
● combined terminal bottom
product feature
● halogen-free
● sealable
● silicon-free
product extension / installable / supplementary devices
Product function Short circuit
Connections
Mechanical Design
Environmental conditions
Certificates
5SJ42027HG41 Page 2/4
55 °C -25 °C
-40 °C 75 °C
F
4.30.2021
Subject to change without notice © Copyright Siemens
product function / note
breaking capacity short-circuit current (Icn) / at AC / acc. to UL 1077 and CSA C22.2 No.235
connectable conductor cross-section / finely stranded / with core end processing
● minimum
● maximum
tightening torque / with screw-type terminals
● maximum
position / of power supply cord
height
width
depth
installation depth
number of modular width units
fastening method
mounting position
net weight
influence of the surrounding temperature
vibration resistance
ambient temperature / during operation
● minimum
● maximum
ambient temperature / during storage
● minimum
● maximum
reference code
● acc. to DIN EN 61346-2