K24 Turbine Digital Diesel Oil Fuel Flow Meter Gauge For Chemicals Liquid Water

Unsold $52.78 Buy It Now or Best Offer, $3.30 Shipping, eBay Money Back Guarantee
Seller: biaoh8077 ✉️ (19) 91.3%, Location: Beijing, CN, Ships to: WORLDWIDE, Item: 314589905445 K24 Turbine Digital Diesel Oil Fuel Flow Meter Gauge For Chemicals Liquid Water. Features:
-The K24 meter feature with complete function of flow meter.
-Simple structure, easy to operate and replace internal components.
-Apply for oil industry, chemicals, medicine, food industry and commercial.
Specifications:
Product Name: Flow Meter
Model: K24
Material: Plastic Structure + Rubber Case
Color: White + Blue
Sizes: About 10 x 7 x 5.5cm(L x W x H)
Import-Export: 1''
Repeatability:± 0.5%
Measurement accuracy: ± 1%
Maximum working pressure: 0.6MPa
Operating voltage: 2.3-3.3V
Standby time: 2 year
Flow range: 10-120L/Min
Single count: 0.00 - 999.9
Total cumulative count: 0.00 - 999999.9
Error Coefficient: 0.1000-9.9999
Unit of measurement: L / Gal / Pts / Qts
Operating temperature: -10 ° C to 35 ° C
Battery Specifications: LR1N x 2 (AAA Size)
Application: Diesel, Adbule, Kerosene, Chemicals, Gasoline
Battery And Maintenance:
1. When the battery voltage in the 2.2V to 2.4V, LCD display shows LBat, to remind the user need to replace the battery.(the user is recommended to replace the battery every year, once a year to check the battery electrode).
2. If there is corrosion should be promptly removed, a long time without the use of flow meter, the battery should be removed.

Unit Choose:
Step 1. Press the CAL + RESET button for 5 seconds in the standby state or the current fill level display to enter the unit conversion settings.
Step 2. Press the RESET button to select LTR → GAL → PT → QT → LTR, then press the CAL button for 3 seconds to exit the unit conversion setting.

Calibration Error Coefficient:
Step 1. Press the MENU button for 3 seconds in the standby state or the current filling amount display status to enter the error coefficient calibration state.
Step 2. Press the RESET button to change the value of the current flashing digit, from 0 to 9, then to 0, and then press the MENU button to move the cursor to the first digit, press the MENU button, digit shift, (flashing digital displacement).
(Note: The larger the coefficient, the less oil, the smaller the coefficient, the more oil.)
Step 3. Press the MENU button for 3 seconds to end the calibration of the error coefficient.

Reseting And Reset Total:
Step 1. Wait for the display to show normal standby display page(with total only displayed)
Step 2. Press the reset key quickly.
Error Coefficient Adjustment Example:
If the original coefficient of 1.000, the display shows 100 liters of oil, the actual oil is 100 liters.
If you want to add less 2 liters of oil, press the MENU button for 3 seconds, according to the error coefficient calibration in the transferred to 1.020, the future is 98 liters. Want to 96 liters on the tune to 1.040.

Package Included:
1 x Fuel flow meter
  • Condition: New
  • Brand: Unbranded

PicClick Insights - K24 Turbine Digital Diesel Oil Fuel Flow Meter Gauge For Chemicals Liquid Water PicClick Exclusive

  •  Popularity - 0 watchers, 0.0 new watchers per day, 312 days for sale on eBay. 0 sold, 1 available.
  •  Best Price -
  •  Seller - 19+ items sold. 8.7% negative feedback. Good seller with good positive feedback and good amount of ratings.

People Also Loved PicClick Exclusive