See Details on eBay Amazon Watch Contact

Elimia ALMS 17-25-230 7.5 HP 208-230V Magnetic Motor Starter Nema 1 UL Listed

$84.00 Buy It Now 10d 12h, Click to see your shipping cost, 30-Day Returns, eBay Money Back Guarantee

Seller: elimia_sales (6,454) 100%, Location: Attalla, Alabama, Ships to: US & many other countries, Item: 372121387216 New Model! Low cost UL listed model ALMS. Available up to 10 HP 230V 3 phase and 5 HP 230V 1 phase. Also available in 480V and 600V models with coil voltages of 24VAC and 120V. High quality, easy to install IEC motor starter. UL 508A Listed. This Motor Starter is a complete unit ready to be installed. Nothing to add. It uses momentary push button switches integrated in the enclosure. Momentary activation uses wiring through the auxiliary contact on the starter to "latch" the starter on until the stop button is pressed or the overload trips. Momentary controls are not meant to be used with machines requiring limit switch controls such as pumps running from limit switch "on-off" commands.The enclosure has a steel stamped base and polymer cover and is rated Nema type 1.Every Motor Starter is assembled and tested to order in Alabama, USA. Our customer's come back time and time again, try one and you will see... Nothing else in this price range even comes close. Please call us if you have any questions. We want you to get the right equipment - 1-855-4Elimia. We offer an extensive line of standard motor starters as well as custom built units. Combination starters and reversing starters are also available in standard and custom configurations. Model Number: ALMS 17-25-230 Model Explanation: ALMS = Latching Start/Stop push button 17-25 = Overload Size 230 = Coil Voltage (works from 196V to 250V, Good for 208V power) Sized for 7.5 HP @ 208-230V 3 phase motor NOTE: pictures may be of another model with the same size specs. Item you will receive is detailed in the above specifications.It is our standard to use oversized contactors except where limited by box size versus contactor size. Using a contactor rated larger than load size will add life to your starter. With IEC type starters this oversizing makes them comparable to Nema sizing.To size your starter properly you must determine the following: -Three phase or Single phase -Supply voltage ie. 120V; 208V; 240V; 480V; 600V -Machine single motor HP -Motor FLA (full load Amps) -Application, what type of machine you running If your supply Voltage is 208V and you want to use your supply power to power the contactor coil... Our 230/240V coils are rated down to 196 Volts. Now, under most cases our standard 230/240V coil will work flawlessly on 208V systems. But, if your machine is very large for your electrical service OR your wiring run is long or undersized I recommend using a separate 120V source for the coil power. Ratings of contactor used in this starter: Size 25 Contactor 3 phase- 10 HP @ 230 VAC Max FLA 28 Amps Control voltage is 230 VAC and is pre-wired. (Note: the power source for the control wiring of this starter is pre-wired and sourced from your feeder wiring directly on the line side of the starter. You will not need to pull in a separate power source for the controls). The control voltage is the voltage used to activate the coil of the contactor. In the simplest install you will want a coil voltage the same as your power supply. But is some cases you might want the control voltage to be different for a host of reasons. The overload will have an adjustable Amperage range. Your overload choice is based on your machines FLA. If your machine motor has a FLA of 10 Amps at your supply voltage then you should choose the overload where 10 Amp falls within the adjustable range. For a 10 Amp FLA we would recommend overload 9 - 13 Amps. Our overloads can be set for manual or automatic reset operation. The overload control is pre-wired by Elimia in a way that trips the starter. This is done to protect your equipment and is one of the main purposes of a motor starter. Overloads reset should never be set to auto for motor starters using a maintained type switch. This will cause the starter to reset and restart without warning when the thermal point is reached. Our standard overload is thermal type class 10A. 90 day replacement Elimia warranty. Great price! We have pre-wired motor starters available from 0 HP to 200 HP. Please call 1-855-4Elimia for more info or if we can help sizing a starter. Guarantee: Satisfaction Guaranteed! If you are not happy with your purchase within two weeks of arrival you can return it. No restocking fee! Offer excludes shipping and eBay fees. If the item has been installed and it turns out not be what you needed please call us. We will work with each customer and try to reach a resolution. Please note: All items should be professionally inspected and tested prior to installation or use. We are not liable for damages, injuries or death relating to our products. Payments: We accept Paypal and Credit Card payments. Credit card payments are only accepted over the phone. We reserve the right to refuse payment from buyers registered in foreign countries or locations with non corresponding ship to addresses. Additionally, we reserve the right to refuse payment from any buyer which will feel is acting in a possible malicious manner. Feedback: Once you are satisfied with your purchase please leave us feedback. If you have any problem with the transaction or product, please contact us. Condition: New, Brand: Elimia, Model: ALMS 17-25-230, MPN: ALMS 17-25-230, Main Voltage: 208-230V 3 phase, Control Voltage: 208-230V, HP Rating: 7.5 HP 208-230V 3 phase

PicClick Insights PicClick Exclusive
  •  Popularity - 591 views, 1.6 views per day, 380 days on eBay. Super high amount of views. 4 sold, 7 available.
  •  Price -
  •  Seller - 6,454+ items sold. 0% negative feedback. Top-Rated Seller! Ships on time with tracking, 0 problems with past sales.
Similar Items