Series | HY inverters | |
Control Mode | SPWM | |
Input Power | 230V class: 220± 15% | |
5-Digits Display & Status Indicator Lamp | Displaying frequency, current, revolution, voltage, counter, temperature, FOR or REV rotation, and fault, etc. | |
Communication Control | RS-485 | |
Working Temperature | -10~40℃ | |
Humidity | 0-95% Relative Humidity( without dew) | |
Vibration | Below 0.5G | |
Frequency Control | Range | 0.1~400.0Hz |
Accuracy | Digital: 0.1%( -10~40℃); Analog: 0.1% ( 25± 10℃ ) | |
Setting Resolution | Digital: 0.1Hz; Analog: 1‰ of max. Operating frequency | |
Output Resolution | 0.1Hz | |
Operator Setting Method | Press directly ← ∧ ∨ to set. | |
Analog Setting Method | External Voltage 0-5V, 0-10V, 4-20mA, 0-20mA. | |
Other Functions | Frequency lower limit, starting frequency, stopping frequency, three skip frequencies can be respectively set. | |
General Control | Ramp Control | Selectable 4-speed steps ramp-up and -down time (0.1-6500s). |
V/F Curve | Set V/F curve at will. | |
Torque Control | Torque increase settable by max. 10.0%. The starting torque can reach 150% at 1.0Hz. | |
Multi-Inputs | 6 multi-function input terminals for 8–speed steps control, program operation, switching of 4-speed Ramp, UP/DOWN function, counter, external emergency stop and other functions. | |
Multi-Outputs | 5 multi-output for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings. | |
Other Functions | Auto Voltage Regulation( AVR) , Decelerating Stop or Coasting Stop, DC Braking, Auto Reset and Restart, Frequency Track, PLC Program Control, Traverse Control,Drawing Control、 Auto Energy Saving, Carrier Adjustable (Up to 20KHz), etc. | |
Protection Functions | Overload Protection | Electronic relay protection motor drive Drive( for constant torque 150%/1 min. for the kinds of fan 120%/1min.) |
Fuse Protection | When the fuse breaks , the motor will stop. | |
Over-voltage | 220V class: DC Voltage > 400V 380V class: DC Voltage > 800V | |
Under-voltage | 220V class: DC Voltage < 200V 380V class: DC Voltage < 400V | |
Restart After Instant Stop | Restart with Frequency Track after Instant Stop | |
Stall Protection | Stall protection in ramp operation | |
Output Short Circuit | Electrical circuit protection | |
Other Functions | Fin over-heat protection, restriction of reverse running, direct start after power on, fault reset, parameter lock PID, one-drive-more, etc. |