3400 Watt / 180 AMP / PMA Alternator Generator PC1212DC 12V Engine Hydro

$469.99 Buy It Now, Click to see shipping cost, 14-Day Returns, eBay Money Back Guarantee
Seller: wind_turbine_generator ✉️ (4,620) 100%, Location: Lancaster, California, US, Ships to: US & many other countries, Item: 332567824925 3400 Watt / 180 AMP / PMA Alternator Generator PC1212DC 12V Engine Hydro. NOT FOR WIND TURBINES made for engine and hydro use only. Below is a video of our dual-core model This Auction is for a #PC1212DC-PMA
  • HIGH POWER
  • COMPACT
  • LIGHT WEIGHT
 VOLT AND HIGH AMPS

12-24 volt battery charging 2800 RPM   180 amps / 3400 Watts

Run faster for 24 volt battery charging  and slower for 12 volt battery charging.

(BEST if used for 12 volt Battery charging)

Works for Lead-acid and large Lithium battery banks. 

Coils are quad wound/ heavy wires for a century  of 

operational life. High Quality - Built by American's.

2700 RPM MAXIMUM! 1095 RPM for >11 Volt battery charging.  OPEN VOLTAGE 1680RPM for >15 Volt battery charging.  OPEN VOLTAGE 2140 RPM for >19 Volt battery charging.  OPEN VOLTAGE 2780 RPM for >32 Volt battery charging. OPEN VOLTAGE     3400 Watts peak power! Closed voltage is always the voltage of the battery bank. The battery dominates the voltage spectrum so a battery can take on higher input voltages easy. Note: You must use a battery regulator when using an unregulated PMA for charging to make sure the battery does note go above its maximum voltage range.  As long as the battery is below its maximum range it can take in-rush of higher voltages without any problems but it may never exceed its maximum range so you need a battery regulator to ensure safe charging. See this link for a regulator: http://www.ebay.com/itm/233211640932 GET YOUR BATTERIES CHARGED UP REAL FAST ON THOSE   GLOOMY WINTER DAYS WITHOUT ANY SOLAR OR WIND.  Use a simple gas lawn mower engine. Keeps your batteries alive when using a power inverter during power outages.   #PC1212 - Power Core is one of our highest amperage PMA's! SEE VIDEO ON HOW TO USE IT. CLICK HIGHLY EFFICIENT - USE LESS GAS OR DIESEL AND MAKE TWICE THE ELECTRICITY USING A BATTERY AND POWER INVERTER!

BEATS TYPICAL 110/220-VAC GENERATORS BY 35% MORE EFFICIENCY.

Also highly recommended for engine, hydro and belt driven applications! The wire size in these stators are extra large coils offering HIGH amperage. This wire is not fine enough for wind power applications   Includes cooling fan and pulley as standard equipment. DO NOT REMOVE COOLING FAN! This model can get hot! VERY POWERFUL!!   Build a super battery charger out of any old lawn mower.  

 

Specially made for belt drive use on engines or direct drive Hydro systems.

Lawn mower not Included.

  THE WORLDS HIGHEST AMPERAGE PMA FOR IT'S SIZE AND CLASS RANGE !   Brand new, never used PMA!   Including the pole shoes and stator coil frame!   We make our own brand new ROTOR POLE SHOES AND STATOR CORES!!!
    Make sure your rotor is brand NEW and has also been re-balanced on a dynamic  rotor balancing machine or your PMA will NOT spin smoothly!!!   Our PMA's are NOT re-built units starting with 'Junk Yard' alternator parts. Our NEW rotor poles are balanced to within .002 grams for SMOOOOOTH rotation!     Includes 60mm pulley and cooling fan FREE!   LOW COGGING  / Power-Core PMA's have amazing power and GREAT low speed start up! Can be run Clock Wise (CW) or Counter Clock Wise (CCW) but when running CCW the shaft requires a "Carter pin lock" to keep the pulley from coming off the shaft. A must have item for off grid emergency power for those days when there is no sun or wind!   2800 RPM MAX!  
  By Hornet Power Systems     Use these powerful permanent magnet alternators (PMA's) to make cheap electricity with wind turbines   Stop wasting up to 50% of your power energizing the coil of standard brush type alternators. Get a real PMA!   Permanent magnet alternators are by no means standard "Automotive" alternators containing brushes and electro-magnetic coils. A PMA does not waste power by having to continuously create an energy intensive magnetic field.   We sell only highly efficient - long lasting true permanent magnet alternators with Neodymium Magnets!
14 powerful  magnetic  power points -  Arranged in a Superbly balanced and perfectly phase biassing configuration. This new design feature offers high power with no appreciable cogging once at running speed.   All magnets are all slotted into multi-layered steel plates for maximizing and sharing the rear field forces boosting the overall core power.   When ordinary stator coils are hyper magnetically saturated with the Power-Core s powerful magnetic field, power outputs are almost tripled over older mono core designs!
  "The PC series PMA' are the most versatile PMA's we have ever built"    
  • LOTS OF LOW END POWER GENERATION ABILITY!!!!
  • Perfect for building simple, inexpensive and dependable wind turbines.
  • A put-up and forget design! Expect decades of dependable service life.
  • All weather rated. Rain, ice and weather proof electronics.

  • 17MM hardened shaft.
  • Heavy Duty coils and diodes.
  • Light weight aluminum body.
  • Bearings rated for 115,000 hours +
  • D.C. output. Includes built in rectifier.
  • Warranty - 90 days parts and labor.
  • Powerful  Neodymium magnets in rotor.

    Includes FREE pulley and cooling fan !! Bi-rotational. Makes power when turned in either direction.  

Pulley and fan comes with all models!

(Smaller pulley sizes will slip on this ultra powerful model)   PC series PMA's weigh 14 LBS. - Size 8" X 7" X 7"  
WARNING; High voltage PMA's and battery banks can cause lethal electric shock!
PLEASE NOTE: Our model numbers have nothing to do with voltages, they are just model numbers GET FREE HOT WATER WHEN YOU USE WATER COOLED ENGINES

 

PMA Testimonials
  I don't know if you remember me about 2 years ago I was asking you questions about your PMA's. They are great, attached is a photo of my engine setup that has over 5000 hours on them. I've just completed a 48 volt system and now am looking to finding out something about your HT48. At what wind speed does it start producing 48 volt power - even 10 watts? I'm thinking of putting two in series, isolating the ground or case in order to get them to produce something at a low wind speed.     Thanks Bill Miller  
WARNING!! Make sure you connect a PMA to the correct battery polarity. Positive PMA to positive battery terminal and negative PMA to negative battery terminal. IF you reverse the connections you will burn out your PMA as the power rushes past the blocking diodes and melts your coils!!! 

HEAT WARNINGS: Keeping your PMA's cooled, fused and under reasonable loads is the operators full responsibility. Monitor your PMA for excessive heating in all experimental machinery! Maximum PMA's operating temperature is 350 F. for 100% duty cycle. No warrantees on ANY burned out PMA's! They are sold in good working condition and you have to keep them cool and never over loaded regarding amperage draw.   A PMA RUNNING SLOW WHILE DRAWING A FULL AMP LOAD IS A DEAD PMA! Here is guide to help you choose the right PMA and keep it cool via the correct RPM V. AMPS coefficient These figures must then be matched to the power curves. This total calculation must be done correctly or you may find yourself burning up a few PMA's as part of your learning curve. (Expensive lessons for the inexperienced!)   This advice is ONLY a guide line and is not a guarantee of cool operation since your amp load can still be to extreme for proper cooling. Don't pull more amperage than the PMA can handle. If you burn one up you own it!!! No warranties on burned up PMA's!!! All sales Final. If you are an amateur and do not understand electrical windings and how much heat they can take please don't buy one of our PMA's. If you are experienced watch for over heating and be careful. These PMA's really pack LOTS of POWER in a small package! Small power to size ratios always means High Performance so be careful!  

TECH NOTES:   Taking apart a PMA the right way.   1. Remove the 4 housing bolts and pull the front housing off OVER the shaft. Never pull the rear housing off first!!!! If it is jammed or rusted use some WD-40 on the shaft and alternately tap the mounting wings with a hammer while applying pressure to the shaft with your thumb so that the stator and it's delicate wiring harness is kept in place. NOTE: If the shaft is QCored-up badly you may have to sand the shaft down to it's original 17mm size to get the front housing off.   2. Now grab the exposed rotor core shaft and pull it out WHILE holding down the stator ring with your index finger and thumb. This will take LOTS of strength!!!!! If you fail to hold the stator in place the core and stator will be extracted together and the wires will be torn off of the stator and this is unrepairable! This is a tricky maneuver and usually takes some experience and lots of muQCle!!!!!!!   3. Once the rotor core has been successfully extracted the rectifier connections are exposed and you may now unfasten the three wire nuts to safely remove the stator coil. (To reassemble simply reverse procedure) "https://hydrogenappliances.com/12si_draft.jpg"   Warranties will be void on any PMA that is opened by a customer. Any PMA experimentation and examination is at your own risk.    

CLICK DRAWING TO ENLARGE

 
 

  • Condition: New
  • Brand: windmill thermodyne
  • Current Output: 100 A or Greater
  • Current Type: DC
  • Power Source: Water
  • Model: GAS ENGINE BATTERY BOOSTER
  • MPN: Windturbineusa.com
  • Country/Region of Manufacture: United States
  • Wire Gauge: 8 awg
  • Power: 3400 Watts

PicClick Insights - 3400 Watt / 180 AMP / PMA Alternator Generator PC1212DC 12V Engine Hydro PicClick Exclusive

  •  Popularity - 125 watchers, 0.1 new watchers per day, 2,242 days for sale on eBay. Super high amount watching. 33 sold, 10 available.
  •  Best Price -
  •  Seller - 4,620+ items sold. 0% negative feedback. Great seller with very good positive feedback and over 50 ratings.

People Also Loved PicClick Exclusive