Hewlett Packard E6000A Mini-OTDR With E6001A SM 1310nm OTDR Module
Dynamic Range: 1310 nm : 28 dB
Includes Carrying Case & Accessories As Listed Above!
Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 90 Day Exchange Warranty
Agilent E6000A Mini OTDR Mainframe
The Agilent Mini-OTDR is the best selling product in Agilent's portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.
The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.
Features - High dynamic range: 40 dB - Automatic fiber characterization - Built-in multi-fiber test - Fiber break locator mode - Full remote control - Simple one-button operation - Context-sensitive on-line help - Automatic event adjustment - Front connector check - Compliant to Bellcore GR-196-CORE trace format - Stabilized continuous wave (CW) light source - Minimum sampling resolution: 8cm - 15 seconds power up cycle - Small and light
Characteristics
Horizontal Parameters - Start-km: - 0 km to 400 km Span: 0.1 km to 400 km - Readout resolution: 0.1 m - Minimum sample spacing: 4 cm - Refractive index: 1.00000 to 2.00000 - Length unit: km, ft, or miles - Measurement points: up to 64000
Vertical Parameters - Vertical scale: - 0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB - Reflectance range: 14 dB to 60 dB - Backscatter coefficient: 10 to 70 dB at 1 s
Storage - 3.5 floppy disk drive: - for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points). - Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points
Interfaces
RS232C: - Maximum transmission rate: - 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds. - Centronics: Standard parallel port (SPP). - Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.
General - Automatic setup analysis - Instrument settings: storage and recall of user-selectable instrument settings. - Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).
Built-in Applications - Automatic Multi Fiber Test - Pass/Fail Test - Fiber Break Locator - Power Meter / Loss Test mode 1 - Visual Fault Finder mode 1 - Optical Return Loss - End to End Loss - Easy OTDR - OTDR Training - OTDR Assistant
Environmental - Operating Temperature: - 0 to 50 degees C Storage Temperature: 40 to +60 degrees C - Humidity: 95% R.H from 0 to 40 degrees C
Power - AC: 100 240 Vrms - 10% 50 60 Hz DC: 16 24 V - External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating - Low battery indicator - Battery charge status
E6001A Specifications:
Central wavelength |
1310 ± 25 nm |
Fiber type |
single-mode |
Pulsewidth |
10 ns
|
100 ns
|
1 µs
|
10 µs
|
Dynamic Range [dB]
|
13
|
18
|
23
|
28
|
Event deadzone |
5 m |
Attenuation deadzone |
25 m
|
Laser safety class: |
21 CFR Class I, IEC825 Class 3A |
Operating temperature: |
0 °C to +50 °C |
Storage temperature: |
-40 °C to +60 °C |
Humidity: |
95 % R.H. from 0 °C to +40 °C |
|