Description:
AF750-30-11 24-60V DC A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 24-60 V, DC This ABB contactor was deemed excess inventory because of a system upgrade. It has been tested for trip to ensure safety. There are no cracks or warping. Once you place your order I will carefully package and ship your ABB Contactor within 24 hours via FedEx. Thank You for your business. Note: price reduced September 25th... We consider reasonable offers. Specs: Dimensions Product Net Depth: 242.0 mm Product Net Height: 283.0 mm Product Net Weight: 15.000 kg Product Net Width: 210.0 mm Technical Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 1 Number of Auxiliary Contacts NC: 1 Rated Operational Voltage: Main Circuit 1000 V Rated Frequency (f): Main Circuit 50 Hz Main Circuit 60 Hz Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1050 A Rated Operational Current AC-1 (Ie): (690 V) 55 °C 875 A (690 V) 40 °C 1050 A (1000 V) 40 °C 1000 A (1000 V) 55 °C 875 A (690 V) 70 °C 720 A (1000 V) 70 °C 720 A Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 300 A (690 V) 55 °C 650 A (415 V) 55 °C 750 A (220 / 230 / 240 V) 55 °C 750 A (440 V) 55 °C 750 A (380 / 400 V) 55 °C 750 A (500 V) 55 °C 750 A Rated Operational Power AC-3 (Pe): (500 V) 520 kW (690 V) 600 kW (220 / 230 / 240 V) 220 kW (380 / 400 V) 400 kW (440 V) 450 kW (415 V) 425 kW Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3 Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3 Short-Circuit Protective Devices: gG Type Fuses 1000 A Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 60 cycles per hour Rated Operational Current DC-1 (Ie): (850 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A Rated Operational Current DC-3 (Ie): (850 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A Rated Operational Current DC-5 (Ie): (850 V) 3 Poles in Series, 40 °C 1050 A (600 V) 3 Poles in Series, 40 °C 1050 A (110 V) 1-Pole, 40 °C 1050 A (110 V) 2 Poles in Series, 40 °C 1050 A (220 V) 3 Poles in Series, 40 °C 1050 A Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV Mechanical Durability: 3 million Maximum Mechanical Switching Frequency: 300 cycles per hour Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C Rated Control Circuit Voltage (Uc): DC Operation 24 … 60 V Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 780 V·A Holding at Max. Rated Control Circuit Voltage DC 5.5 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Pull-in at Max. Rated Control Circuit Voltage DC 785 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 780 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Operate Time: Between Coil Energization and NO Contact Closing 50 ... 120 ms Between Coil De-energization and NO Contact Opening 53 ... 73 ms Between Coil De-energization and NC Contact Closing 50 ... 70 ms Between Coil Energization and NC Contact Opening 45 ... 115 ms Connecting Capacity-Main Circuit: Rigid Al-Cable 300 mm² Bar 52 mm Rigid Cu-Cable 300 mm² Connecting Capacity-Auxiliary Circuit: Solid 1x1…4 mm² Flexible with Insulated Ferrule 2x0.75…2.5 mm² Stranded 2x1…4 mm² Flexible 2x0.75…2.5 mm² Flexible with Ferrule 2x0.75…2.5 mm² Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 Terminal Type: Main Circuit: Bars Number of Main Contacts NO: 3 Technical UL/CSA General Use Rating UL/CSA: (600 V AC) 900 A Horsepower Rating UL/CSA: (208 V AC) Three Phase 250 Hp (440 ... 480 V AC) Three Phase 600 Hp (550 ... 600 V AC) Three Phase 700 Hp (220 ... 240 V AC) Three Phase 300 Hp (200 V AC) Three Phase 250 Hp Maximum Operating Voltage UL/CSA: Main Circuit 600 V Certificates and Declarations (Document Number) Instructions and Manuals: 1SFC380023-en BV Certificate: 11727/C0 BV CB Certificate: SE-69481 CCC Certificate: CQC_2007010304256684 CSA Certificate: 306712-1 Classifications E-nummer: 3228362 ETIM 4: EC000066 - Magnet contactor, AC-switching ETIM 5: EC000066 - Magnet contactor, AC-switching UNSPSC: 39121529 Object Classification Code: Q